This manual provides essential guidance for your Everstar portable air conditioner, covering operation, maintenance, and troubleshooting for optimal performance and extended unit life.
Everstar portable air conditioners represent a convenient and efficient cooling solution designed for individual room comfort. Unlike traditional window units or central air systems, these units offer the flexibility of portability, allowing you to direct cooling where it’s needed most within your home.
These appliances are multi-functional, providing not only cooling but also dehumidifying and fan-only modes for versatile climate control. The included outflow hose and window kit facilitate easy setup, enabling quick and effective cooling in any suitable room.
Everstar units are engineered for ease of use, featuring intuitive control panels and straightforward operation. They are ideal for bedrooms, offices, or any space requiring targeted cooling without the complexities of permanent installation.
Key Features and Benefits
Everstar portable air conditioners boast several key features designed for user convenience and optimal performance. These include multiple operating modes – cooling, fan, and dehumidifying – providing versatile climate control options. The adjustable temperature settings and fan speeds allow for personalized comfort levels.
A notable benefit is the inclusion of a turbo mode, enabling rapid cooling for quicker temperature reduction. The swing function distributes air evenly throughout the room, enhancing cooling efficiency.
Portability is a significant advantage, eliminating the need for complex installation. Furthermore, the easy-to-empty water tank and washable air filter contribute to simplified maintenance and long-term usability.

Understanding Your Everstar Unit
Familiarize yourself with your Everstar portable air conditioner’s components and specifications to ensure proper setup, operation, and maintenance for efficient cooling.
Model Identification and Specifications
Identifying your Everstar portable air conditioner model is crucial for accessing specific support and replacement parts. Locate the model number and serial number on the unit’s label, typically found on the back or side panel. This information is also vital when contacting customer service.
Everstar portable air conditioners are designed for individual room cooling and offer varying cooling capacities, measured in BTUs (British Thermal Units). Common BTU ratings range from 8,000 to 14,000, influencing the area size the unit can effectively cool.
Key specifications include voltage (typically 115V/60Hz), power consumption (in watts), and water tank capacity. Understanding these specifications ensures safe and efficient operation. Refer to your unit’s specific documentation for detailed specifications tailored to your model.
Package Contents: What’s Included
Upon unboxing your Everstar portable air conditioner, carefully verify that all components are present. The standard package typically includes the air conditioner unit itself, an exhaust hose for venting hot air, and a window kit designed for easy installation in standard windows.
Additionally, you should find a remote control for convenient operation, and potentially batteries for the remote. Some models may include a drain plug or hose for water removal from the internal tank.
Always retain the original packaging for potential warranty claims or future transport. A detailed parts list is usually included in the instruction manual, allowing you to quickly confirm all items are accounted for. Contact customer support immediately if any components are missing or damaged.

Setting Up Your Air Conditioner
Proper setup is crucial for efficient operation. This involves securely installing the exhaust hose and window kit, ensuring effective ventilation and optimal cooling performance.
Installing the Exhaust Hose and Window Kit
Proper installation of the exhaust hose and window kit is vital for efficient operation. Begin by connecting the exhaust hose to the back of the air conditioner unit, ensuring a secure fit. Next, assemble the window kit according to the included diagrams, adjusting the length to match your window size.

Carefully insert the window kit into the window opening and seal any gaps with the provided foam strips to prevent warm air from re-entering the room. Connect the exhaust hose to the window kit adapter, again ensuring a tight connection. It’s crucial to vent hot air outside for optimal cooling. Double-check all connections for leaks and stability before powering on the unit. A poorly installed kit significantly reduces cooling efficiency.
Powering On and Initial Setup
Before initial use, ensure the air conditioner is placed on a level surface and the exhaust hose is correctly installed. Plug the unit into a grounded electrical outlet. Press the power button to turn on the air conditioner. Initially, set the temperature to a lower setting and the fan speed to a medium level.
Allow the unit to run for a few minutes to circulate cool air and stabilize. Periodically check the water tank to avoid overflow. Familiarize yourself with the control panel functions, including cooling, fan, and dehumidifying modes. The turbo mode will quickly reach the desired temperature. Adjust settings as needed for your comfort.

Operating Instructions
This section details how to effectively use your Everstar portable air conditioner, covering all modes, adjustments, and features for optimal cooling and comfort.
Control Panel Overview
The control panel is your central hub for operating the Everstar portable air conditioner. It features intuitive buttons for power, mode selection (cooling, fan, dehumidifying), temperature adjustment using up and down arrows, and fan speed control.
A dedicated “Turbo” button rapidly cools the room, while the “Swing” button adjusts the air vent direction in six-degree increments. Understanding these controls is key to customizing your cooling experience. The panel also displays the currently selected temperature and fan speed.
Regularly check the water tank indicator, as overflow can occur. Familiarize yourself with each button’s function to maximize the unit’s efficiency and enjoy consistent, comfortable cooling. Proper use ensures optimal performance and longevity of your Everstar appliance.
Cooling Mode Operation
To activate cooling mode, press the “Cool” button on the control panel. Use the up and down arrow buttons to set your desired temperature; the unit will automatically adjust to maintain it. For faster cooling, engage “Turbo” mode, which maximizes fan speed and compressor output.
Ensure the exhaust hose is properly installed and sealed to a window using the provided kit, preventing warm air from re-entering the room. Regularly check the water tank, as cooling generates condensation. The swing function distributes cool air evenly.
Monitor the room temperature and adjust settings as needed for optimal comfort. Cooling mode efficiently lowers room temperature and provides relief from heat, offering a convenient and effective solution.
Fan Mode Operation
To operate in fan mode, press the “Fan” button on the control panel. This mode circulates air without actively cooling it, providing ventilation and a refreshing breeze. Utilize the fan speed button to select from multiple settings – low, medium, or high – adjusting the airflow intensity to your preference.
Fan mode is ideal for days when cooling isn’t necessary but air circulation is desired. The swing function can be used in conjunction with fan mode to distribute air throughout the room. Remember, fan mode does not remove moisture from the air.
This mode consumes less energy than cooling mode, offering an economical way to maintain air movement and comfort.
Dehumidifying Mode Operation
Activate dehumidifying mode by pressing the designated “Dehumidify” button on the control panel. This function removes excess moisture from the air, creating a more comfortable environment, particularly in humid conditions. The unit will operate quietly, drawing in air and condensing moisture, which is collected in the internal water tank.
Regularly emptying the water tank is crucial for optimal performance; a full tank will trigger an automatic shut-off. Fan speed can often be adjusted within dehumidifying mode to control the rate of moisture removal. This mode is beneficial for preventing mold and mildew growth.
Dehumidifying mode doesn’t necessarily cool the air, but reducing humidity can feel cooler.
Temperature and Fan Speed Adjustment
Adjusting the temperature is simple: use the “Up” and “Down” arrow buttons on the control panel to set your desired cooling level. The display will show the target temperature. Fan speed is controlled separately, offering options like “Low,” “Medium,” and “High.” Experiment to find the balance between comfort and energy efficiency.
Higher fan speeds provide quicker cooling but consume more power. Lower speeds are quieter and more energy-saving. The “Turbo” mode, when activated, maximizes cooling by running the fan at its highest setting. Remember to periodically check the water tank, as increased cooling often leads to more condensation.
Precise temperature control ensures personalized comfort.
Using the Swing Function
The swing function allows you to adjust the direction of the airflow for wider room coverage. Each press of the “Swing” button on the control panel will move the air vent approximately six degrees, either up or down. This automated movement distributes cool air more evenly throughout the space, eliminating hot or cold spots.
You can customize the airflow pattern to suit your preferences. For direct cooling, position the vent towards you. For broader circulation, allow the swing function to operate continuously. Remember to ensure the swing isn’t obstructed by furniture or curtains.
Optimizing airflow enhances cooling efficiency and overall comfort.
Utilizing the Turbo Mode
Turbo mode is designed for rapid cooling, quickly bringing the room temperature down to your desired setting. When activated via the control panel, the compressor operates at maximum capacity, and the fan speed is automatically set to its highest level. This delivers a powerful burst of cool air, ideal for quickly combating heat.
While highly effective, turbo mode consumes more energy than standard cooling modes. It’s best used when you need immediate relief from the heat and can be deactivated once the desired temperature is reached.

Remember to monitor the water tank, as turbo mode can increase condensation.

Maintenance and Care
Regular maintenance ensures optimal performance and longevity of your Everstar unit; this includes cleaning the air filter, emptying the water tank, and general cleaning.
Cleaning the Air Filter
Maintaining a clean air filter is crucial for efficient operation and air quality. The air filter should be checked and cleaned regularly, ideally every two weeks, or more frequently if the unit is used in a dusty environment. To clean the filter, first power off and unplug the air conditioner. Then, locate the filter access panel – typically on the rear or side of the unit.
Remove the filter and gently vacuum it to remove loose dust and debris. For a more thorough cleaning, wash the filter with mild soap and warm water, ensuring it is completely dry before reinstalling. Never operate the unit without the air filter in place, as this can damage the internal components and reduce cooling performance. A clogged filter restricts airflow, leading to reduced efficiency and potential overheating.
Emptying the Water Tank
During dehumidifying mode, or in humid environments during cooling, your Everstar portable air conditioner collects condensation in an internal water tank. Regularly emptying this tank prevents overflow and ensures continued operation. The unit will typically display a warning indicator or automatically shut off when the tank is full.
To empty the tank, first power off and unplug the air conditioner. Then, carefully remove the water tank, usually located at the rear or base of the unit. Dispose of the collected water appropriately. Ensure the tank is securely reinserted before resuming operation. Periodically checking the bucket avoids overflow and potential water damage. Some models may have a continuous drain option for automatic water removal.
General Cleaning Procedures
Maintaining a clean Everstar portable air conditioner ensures optimal performance and air quality. Before any cleaning, always disconnect the unit from the power source. Wipe the exterior surfaces with a soft, damp cloth. Avoid using harsh chemicals or abrasive cleaners, as these can damage the finish.
Periodically inspect the exhaust hose and window kit for dust accumulation, cleaning as needed. Ensure the air vents are free from obstructions. General cleaning procedures should be performed regularly, especially during periods of heavy use. Proper care extends the lifespan of your unit and maintains efficient cooling. Remember to dry all components thoroughly before reassembling and operating the air conditioner.

Troubleshooting Common Issues
This section addresses frequent problems with your Everstar unit, including cooling issues, error codes, and water leakage, offering solutions for quick resolution.
Unit Not Cooling Properly
If your Everstar portable air conditioner isn’t cooling effectively, several factors could be at play. First, ensure the exhaust hose is correctly installed and sealed to a window, preventing warm air from re-entering the room.
Check the air filter; a clogged filter restricts airflow, diminishing cooling capacity. Clean or replace it as needed. Also, verify the water tank isn’t full, as some models reduce cooling when the tank is nearing capacity.
Confirm the unit is set to ‘Cool’ mode and the desired temperature is significantly lower than the room temperature. Utilize the ‘Turbo’ mode for faster cooling. If issues persist, inspect for any obstructions blocking airflow around the unit itself.
Error Codes and Their Meanings
Your Everstar portable air conditioner utilizes error codes to signal specific issues, aiding in troubleshooting. While code specifics vary by model, common codes include “E1” or “E2”, often indicating a sensor malfunction – potentially temperature sensor failure requiring professional service.
“E3” frequently signals an issue with the exhaust hose, like a poor connection or blockage, hindering proper operation. “E4” may denote a full water tank, prompting immediate emptying. “P1” or similar codes can relate to compressor problems.

Consult your specific model’s documentation for a complete list and detailed explanations. If an error code appears repeatedly, or you’re unsure of its meaning, contact Everstar customer support for assistance and potential repair options.
Water Leakage Issues
Water leakage from your Everstar portable air conditioner typically stems from a few key areas. A clogged drain hose is a common culprit, preventing proper water disposal during dehumidifying mode; regular cleaning is crucial. An improperly installed unit, lacking sufficient tilt for drainage, can also cause leaks.
Overfilled water tanks, if not emptied promptly, will overflow. Inspect the tank’s seating for secure placement. Internal ice buildup, often due to low temperatures, can melt and cause leakage. Ensure adequate room temperature.
If leaks persist after addressing these points, check for cracks in the tank or hose. Discontinue use and contact Everstar support for repair or replacement.

Safety Precautions
Always operate your Everstar portable air conditioner on a grounded electrical outlet, avoiding extension cords and adapters. Never use a damaged power cord or plug. Keep the unit away from flammable materials and excessive moisture to prevent electrical shock or fire hazards.
Ensure the exhaust hose is properly installed to prevent hot air recirculation and maintain cooling efficiency. Do not block the air intake or outlet vents. Regularly clean the air filter to maintain air quality and prevent unit overheating.